| DISPLAY READINGS |
| Main Voltage |
Displays the operating voltage and the reading is live all the time regardless of the operation functions. |
| Operating time |
Displays the Solenoid’s time until makes the full contact to field coil And this reading is on hold until next test. |
| Deactivate time |
Displays the solenoids fully released time after the “S” terminal deactivated. And this reading is on hold until next test. |
| Voltage Drop |
Displays the voltage loss on contact terminals, between Battery terminal and Field terminal this reading is live as long as “S” terminal is active. As soon as “S”terminal gets release this reading is on hold as well. |
| Current Draw |
Displays the Starter’s Amps draw while the starter is running and stays on hold until the next test.
|
| SPECIFICATIONS |
| Input Voltage |
12-24 V Dc |
| Power consumption |
0.1 A (100 mA) |
| Main Voltage reading |
12.0 - 30.0 Volts |
| Operation time calculation |
0-1000 microsecond (1/1000 second) |
| Release time calculation |
0-1000 microsecond (1/1000 second) |
| Voltage drop |
0-4.00 Volts (1/100 Volts) |
| Amp meter reading |
20-600 Amps |